titulo
Utilizamos cookies propias y de terceros para mejorar tu experiencia y nuestros servicios. Si continúas navegando consideramos que aceptas su uso. Puedes obtener más información sobre cookies aquí
Cerrar
BANNER-1-9-PRONTUBEAM

Transversal reinforcement in the lap zone

October , 25th 2023 | Via: Prontubeam | Seen: 1234 times
Transversal reinforcement is required in the lap zone to resist the transverse tension forces. When the diameter is equal or higher than 20mm or the lapped bars in any section is more or equal than 25%, transverse reinforcement is needed.

This transverse reinforcement should be provided at the outer sections of the lap as presented in the picture, in the 1/3 of the overlap length.

In addition, for bars in compressionm the transverse reinforcement should be placed outside each end of the lap length and within a distance equal to 4 diameters of the ends of the lap lenght as presented in the figure below.
Transversal reinforcement in the lap zone
¿Do you want to publish in Prontubeam? Send us your name, mail and subjet of the article. We will get in touch with you as soon as possible